NABL & ISO/IEC 17025:2017 Calibration Reference Portal
Official Lab Services: multitek.in
Solutions for: Quality Heads & Auditors Shop Floor Inspectors Tool Room Technicians Engineering Students

Calibration Sticker Requirements for Aviation Maintenance Tools

 

A sticker is a status control, not the calibration itself

A calibration sticker gives the technician an immediate point-of-use answer: Is this the correct identified tool, and is its calibration status currently acceptable? It should support the controlled calibration record rather than replace it.

FAA §145.109 does not prescribe a universal sticker design. FAA AC 145-9A instead says calibrated equipment should be identified in a manner that prevents inadvertent use of noncalibrated equipment. Its typical identification information includes a serial number or other unique identification, last-calibration date, next-due date and the name or initials of the person performing calibration. The AC also stresses that the tool itself should remain identifiable if a label is lost or removed. [26]

EASA puts stronger emphasis on visible status

AMC 145.A.40(b) calls for a clear labeling system indicating when the next inspection, service or calibration is due and, where it would not otherwise be obvious, when equipment is unserviceable. It also calls for a precision-tool register and calibration records. [27]

A practical aviation label can therefore contain the asset ID, status, calibration date, due date and any use limitation, while a certificate or controlled electronic record holds the fuller calibration evidence.

What if the sticker is missing?

Do not infer calibration status from appearance or memory. Hold the tool from use until its unique identity and current status can be confirmed from the controlled record, then restore identification according to the organization's approved procedure.

A universal FAA/EASA sticker layout is unspecified in the sources reviewed. The organization should define its label format and alternative status-control method for items where a physical label is impractical.

Field

Example

CALIBRATION STATUS

IN CALIBRATION

Asset ID

TW-0042

Serial No.

SN-EXAMPLE-42

Calibrated

15 Sep 2026

Due

15 Sep 2027*

Limitation

None

Certificate Ref.

CAL-2026-0042

Verified by

QA-07

*Example only. The date must come from the organization's applicable interval rule; 12 months is not presented here as a universal regulatory interval. [28]