A sticker is
a status control, not the calibration itself
A calibration sticker gives the technician an immediate point-of-use
answer: Is this the correct identified tool, and is its calibration status
currently acceptable? It should support the controlled calibration record
rather than replace it.
FAA §145.109 does not prescribe a universal sticker design. FAA AC
145-9A instead says calibrated equipment should be identified in a manner that
prevents inadvertent use of noncalibrated equipment. Its typical identification
information includes a serial number or other unique identification,
last-calibration date, next-due date and the name or initials of the person
performing calibration. The AC also stresses that the tool itself should remain
identifiable if a label is lost or removed. [26]
EASA puts
stronger emphasis on visible status
AMC 145.A.40(b) calls for a clear labeling system indicating when the
next inspection, service or calibration is due and, where it would not
otherwise be obvious, when equipment is unserviceable. It also calls for a
precision-tool register and calibration records. [27]
A practical aviation label can therefore contain the asset ID, status,
calibration date, due date and any use limitation, while a certificate or
controlled electronic record holds the fuller calibration evidence.
What if the sticker is missing?
Do not infer calibration status from
appearance or memory. Hold the tool from use until its unique identity and
current status can be confirmed from the controlled record, then restore
identification according to the organization's approved procedure.
|
Field |
Example |
|
CALIBRATION STATUS |
IN CALIBRATION |
|
Asset ID |
TW-0042 |
|
Serial No. |
SN-EXAMPLE-42 |
|
Calibrated |
15 Sep 2026 |
|
Due |
15 Sep 2027* |
|
Limitation |
None |
|
Certificate Ref. |
CAL-2026-0042 |
|
Verified by |
QA-07 |
*Example only. The date must come from the
organization's applicable interval rule; 12 months is not presented here as
a universal regulatory interval. [28]