Calibration, metrology and measurement

Technical calibration knowledge organized around real measurement decisions

Explore practical guides on dimensional calibration, calibration management, certificates, uncertainty, laboratory selection and developing measurement disciplines.

Instrument procedures Calibration decisions Certificates & uncertainty Industrial measurement

Core expertise

Primary knowledge clusters supported by your published sitemap.

  1. 1. StartChoose the measurement problem
  2. 2. PillarUnderstand the calibration discipline
  3. 3. ProcedureOpen the instrument-specific guide
  4. 4. EvaluateCheck uncertainty, certificate or tolerance
  5. 5. DecideSelect the appropriate technical action

Growing measurement topics

Smaller clusters with published supporting content.

When to Review a Sound Level Meter Calibration Interval

A sound level meter calibration interval should reflect the equipment, its use and the requirements of the measurement task. A due-date sticker is useful for scheduling, but it cannot explain why the interval is suitable. This guide helps you organise an interval review. It does not prescribe a universal annual interval or authorise an extension where a binding requirement sets the timing. Separate fixed obligations from reviewable choices Start by listing applicable contractual, procedural and other requirements. Identify whether each statement is mandatory for your work, a manufacturer's recommendation or an internal scheduling choice. Resolve conflicting instructions before changing the programme. ILAC-G24 / OIML D 10:2022 provides guidance on selecting and reviewing recalibration intervals. It considers equipment history and operating factors, and describes several review approaches. It is guidance rather than a universal timetable for sound level meters. Build one his...
Recent posts

Does Your Acoustic Calibrator Need Calibration?

An acoustic calibrator needs its own calibration programme. It supplies the reference signal used to check other sound measurement equipment. A sound level meter displaying the expected value does not independently establish the calibrator's output. Treat the calibrator as an identified item of measurement equipment. Keep its certificate, condition records and operating instructions available to the people who use it. Understand the reference signal A calibrator produces sound in a coupler designed for a compatible microphone arrangement. Its specified output has a sound pressure level and frequency. The reference used for a check must be appropriate for the actual equipment combination and conditions. For a concrete product example, the Brüel & Kjær Type 4231 data sheet lists nominal outputs of 94 dB and 114 dB at 1 kHz and identifies conformity to EN/IEC 60942:2017 Class 1. Those are model-specific statements, not specifications for every calibrator. Why a meter chec...

Acoustic Calibration: Instruments, Process and Field Checks

Acoustic calibration helps users understand the performance of instruments used to measure sound. It establishes a relationship between instrument readings and reference values under specified conditions, with measurement uncertainty taken into account. A sound level meter may display a stable reading, but that alone does not show that the measurement is reliable. The microphone, electronics, settings and measurement conditions all influence the result. Calibration provides evidence about instrument performance at the points tested. What is acoustic calibration? Acoustic calibration applies measurement standards to sound measurement equipment. Depending on the instrument and method, the work may establish microphone sensitivity, sound pressure level response or the output of an acoustic calibrator. Calibration and adjustment are separate activities. Calibration establishes how readings relate to reference values. Adjustment changes the instrument so that it gives specified indic...

How to Read a Pressure Gauge Calibration Certificate

To read a pressure gauge calibration certificate, match the instrument and pressure mode first. Then check the reported error, units, uncertainty, and acceptance rule at the pressures you use. A pass statement needs to be read with the specification it refers to. This guide works through a small example for a gauge reading in bar. It helps you review returned results; it is not an operating procedure for applying pressure. Contents Match the certificate to the job Read a worked result table Convert a full-scale tolerance Check the acceptance rule Record the release decision Common questions For the broader review process, read Reading Calibration Certificates with As-Found and As-Left Data . Match the certificate to the job. Before calculating anything, put the certificate beside the asset record and calibration request. Use the following questions as a practical review aid, rather than a list of mandatory certificate fields. Questions to resolve before using the result...

Spark OES Generator Calibration and Verification for Metallurgical Analysis

Metallurgical OES Calibration Spark OES Generator Calibration and Verification for Metallurgical Analysis Spark OES generator verification should connect electrical source behaviour with analytical evidence from the complete metallurgical measurement system. Key point Electrical generator verification and analytical OES verification answer different questions. Use the applicable OEM procedure, laboratory procedure, CRM information and controlled acceptance criteria for final decisions. Contents The measurement chain What the generator does Calibration and verification Post-repair verification Metallurgical evidence Return-to-service decision Start with the complete measurement chain A spark optical emission spectrometer does not measure alloy chemistry directly from the electrical output of its generator. The generator initiates and controls an electrical discharge at the sample. That discharge produces the plasma used to ablate, atomize and excite material. The opti...

Pipette Calibration Checks Before Trusting Dispensed Volume

Mass Balance and Volume Review pipette identity, selected volume, tips, test method, environment, balance, results, uncertainty and decision rule before trusting a dispensed volume. Contents Direct answer Calibration, routine testing and adjustment Identify the complete pipetting system Confirm the measurement method Control the balance, liquid and environment Read systematic and random effects separately Apply the correct acceptance requirement Review the calibration certificate Build a useful routine check Direct answer A calibration check label does not set up that every quantity brought with the aid of a pipette is suitable for every method. Consider the result only after confirming the pipette configuration, decided on test volumes, recommendations, measurement approach, environmental controls, dimension uncertainty and attractiveness requirement. ISO 8655-2:2022 covers me...

Can Calibration Data Help Investigate Process Drift?

Calibration Troubleshooting Use calibration history with process records, maintenance events, environmental data, and independent checks when investigating process drift. Contents Can Calibration Data Reveal a Manufacturing Process Problem? Calibration data and process data are different Look for repeated changes Compare dates and equipment records Check the measurement system first Use controlled checks Treat relationships as evidence to investigate Decide what needs correction Investigation checklist Related measurement investigations Can Calibration Data Reveal a Manufacturing Process Problem? Calibration records hold measurement details. Manufacturing records track production activities. When a measurement trend shifts, it’s helpful to review both records. However, it’s crucial to keep their purposes distinct. Calibration data alone doesn’t prove a change in the manufacturing process. It can support the investigation of a possible link. Calibration Data and Process D...