NABL & ISO/IEC 17025:2017 Calibration Reference Portal
Official Lab Services: multitek.in
Solutions for: Quality Heads & Auditors Shop Floor Inspectors Tool Room Technicians Engineering Students

Aircraft Maintenance Calibration Log Template + Required Fields

 

The calibration log is the control register

An aviation calibration log should answer four questions quickly: What is the tool? Where is it? What is its current calibration status? What evidence supports that status?

FAA AC 145-9A recommends a list containing the calibrated equipment name, model or part number, serial number, calibration date and next due date. If employee-owned measuring/test equipment is allowed for airworthiness determinations, the AC says those tools should also be included in the calibration program. [29] Calibration records should additionally capture the person or entity that performed calibration, the standard and method used, results, and identification of measuring/test equipment used in the calibration. The AC specifically emphasizes actual test-point results where calibration history is being used to revise intervals. [30]

EASA AMC 145.A.40 similarly calls for identified precision tooling, a control register and records of calibrations and standards used. [20]

Add operational fields, not just certificate fields

For useful MRO control, add custodian/location, current status, calibration provider, certificate reference, interval basis, limitations, issue/return status and any out-of-tolerance investigation reference.

A spreadsheet can perform this function for a small controlled population, but it needs access control, backups, validation and a defined owner. FAA AC 145-9A's electronic-record guidance emphasizes authorization controls, system integrity, retrieval and periodic backup. [31]

Do not confuse conditional formatting with compliance. A red “OVERDUE” cell is useful only if an effective procedure prevents the corresponding tool from being issued or used.

Copyable calibration-register template

Asset ID

Tool

Make / Model

Serial No.

Location / Owner

Interval basis

Last cal.

Due date

Status

Provider

Certificate ref.

Standard / method

OOT ref.

TW-001

Torque wrench

Example

EX-001

Tool crib

Mfr./QCM

 

 

 

 

 

 

 

DG-002

Dial gauge

Example

EX-002

Inspection

Mfr./QCM

 

 

 

 

 

 

 

The template deliberately separates interval basis from the dates so an auditor can see why the due date exists rather than treating it as an unexplained spreadsheet calculation.